MoFlo XDP Cell Sorter

The MoFlo XDP cell sorter combines high-speed sorting capability with an open flexible design to enable a wide variety of sorting applications.

  • High-speed electronics ensure identification & sort accuracy 
  • Unmatched linearity & true dynamic range of 5 decades
  • Stable fluidic design for precise droplet formation during long sorts
  • IntelliSort II: Beadless drop delay determination and monitoring

MoFlo XDP Cell Sorter Features

Modularity

  • Compatible with any visible wavelength flow cytometry laser
  • Fiber coupled lasers with beam shaping optics for increased stability & alignment ease
  • Precision Optical Detector (POD) structure simplifies filter changes

Performance

  • 70,000 sorts per second (validated)
  • > 99% purity (all data rates)
  • High recovery, yield & viability
  • Proven 4-Way Sort for multiple population sorting
  • Independent Sort Mode capability in each tube
  • CyClone® custom plate & slide sorting

Electronics and Software

  • Negligible dead time
  • > 100,000 analysis events/second
  • Digital triggering on any parameter
  • Digital pulse processing (DPP)
  • Unmatched linearity
  • 18x18 auto-compensation matrix
  • Full parameter resolutions for region determination
  • > 1 billion event listmode files

Biosafety

  • Certifiable iosafety Level I or II cabinet option
  • Aerosol Evacuation System (AES) removes aerosols from sort chamber
  • Replaceable probe & sample line
  • SmartSampler sample input ensures sample & operator protection

Explore MoFlo XDP Models

MoFlo XDP Cell Sorter Specifications

Sorting Performance Configurable with 405, 488, 640 nm lasers
Drop Dive Frequency Adjustable up to 200kHz
Sorting Modes Semi-automated, manual, controlled by operator
Power Requirements 50/60 Hz, 100-230 VAC
Item Specifications Referenced ML99030

Content and Resources

Filter by:
Resource Type
Flow-cell-sorting-moflo-application-note-bacterial-proliferation-and-phb-production Population dynamics were follow ed during growth on phenol in response to adaptation processes of Cupriavidus necato, bacterial individuals morphologically nearly uniform, yet structurally and functionally diverse
Flow-cell-sorting-moflo-application-note-fluorescence-resonance-energy-transfer Fluorescent proteins have become a mainstay in the study of protein localization, protein-protein interaction and gene expression
Flow-cell-sorting-moflo-application-note-chromosome-sorting Flow cytometric chromosome classification (flow karyotyping) has been routinely used in the analysis of mammalian karyotypes as well as to assess chromosomal abnormalities
Flow-cytometers-technical-application-moflo-viability-and-function Sustained cell sorting at speeds in excess of 50,000 events per second is routine when using the MoFlo high-performance cell sorter
Flow-cytometers-moflo-xdp-4way-brochure-sort-power-flexibility-automated The patented 4WAY Sort system is standard on the MoFlo XDP high-performance cell sorter

Technical Documents